Combined Loading Compression (CLC) Composite Fixture

This Combined Loading Compression (CLC) Composite Fixture is constructed out of high quality stainless steel and is recommended to test in accordance with ASTM D6641.

  • Compression
  • Metals
  • Composites
  • ASTM D6641
true
true
true

TECHNICAL OVERVIEW

  • Recommended to test in accordance with ASTM D6641/D6641M
  • Constructed out of high quality stainless steel
  • Supported specimen dimensions
  • Maximum width: 25.4 mm (1 in)
  • Maximum thickness (with tabs): 12.7 mm (0.5 in)
  • Length: 140 mm (5.5 in)
  • Requires compression platens for mounting (purchased separately) 

Combined Loading Compression (CLC) Test Fixture

STATIC FORCE

TEMPERATURE RATING

WEIGHT

DIMENSIONS

PART NUMBER

89 kN

-152 to 318°C

≈ 6.8 kg

107 mm (4.2 in) x

100-351-819

(20 kip)

(-240 to 600°F)

(15 lbs)

53 mm (2.1 in) x

 

 

 

 

140 mm (5.5 in)