Series 295 Hydraulic Service Manifolds

A hydraulic service manifold provides hydraulic isolation between the hydraulic power unit and the test system. This hydraulic service manifold enables smooth transitions of hydraulic pressure to enhance safety and increase predictable control of the hydraulic system. Now available with SafeGuard™ technology for safety Performance Level d and e compliance.

KEY PRODUCT FEATURES

Innovative Technology

Optional SafeGuard Technology protects from unexpected pressure surges

Accurate / Repeatable Results

Soft on/off options minimize system crosstalk, maximizing accuracy

Advanced Safety Features

Rapid dump hydraulic pressure unloading quickly removes hydraulic pressure in potentially hazardous situations

Versatile

Controls up to four test systems independently

MODEL COMPARISON

FULL PRODUCT INFORMATION

295 HSM SPECIFICATIONS

 

 

 

 

 

 

 

295.1XA-XX3X

295.2XA-XX3X

295.2XA-XX4X

295.3XA-XX3X

295.3XA-XX4X

Operating Pressure

 

21 MPa (3000 psi)

21 MPa (3000 psi)

28 MPa (4000 psi)

21 MPa (3000 psi)

28 MPa (4000 psi)

Nominal flow

 

189 lpm (50 gpm)

378 lpm (100 gpm)*

378 lpm (100 gpm)*

946 lpm (250 gpm)

946 lpm (250 gpm)

Variable low pressure

 

1 - 21 MPa (150 - 3000 psi)

1 - 21 MPa (150 - 3000 psi)

1 - 28 MPa (150 - 4000 psi)

1 - 21 MPa (150 - 3000 psi)

1 - 28 MPa (150 - 4000 psi)

Slow on/off ramp time

 

5.0 - 9.0 seconds

5.0 - 9.0 seconds

5.0 - 9.0 seconds

5.0 - 9.0 seconds

5.0 - 9.0 seconds

Maximum current to

solenoid valves

0.3 A at 115 V AC or

1.5 A at 24 V DC

0.3 A at 115 V AC or

1.5 A at 24 V DC

0.3 A at 115 V AC or

1.5 A at 24 V DC

0.3 A at 115 V AC or

1.5 A at 24 V DC

0.3 A at 115 V AC or

'1.5 A at 24 V DC

 

 

 

 

 

 

 

ACCUMULATORS

 

 

 

 

 

 

Pressure

min

max

0.94 L (0.25 gal)

3.8 L (1 gal)

3.8 L (1 gal)

7.6 L (2 gal)

3.8 L (1 gal)

7.6 L (2 gal)

3.8 L (1 gal)

19.0 L (5 gal)

3.8 L (1 gal)

19.0 L (5 gal)

Return

min

max

0.45 L (0.12 gal)

0.94 L (0.25 gal)

1.9 L (0.5 gal)

3.8 L (1 gal)

1.9 L (0.5 gal)

3.8 L (1 gal)

0.94 L (0.25 gal)

7.6 L (2 gal)

0.94 L (0.25 gal)

7.6 L (2 gal)

Pilot pressure

min

max

0.45 L (0.12 gal)

0.94 L (0.25 gal)

0.45 L (0.12 gal)

0.45 L (0.12 gal)

0.45 L (0.12 gal)

0.9 L (0.25 gal)

0.45 L (0.12 gal)

0.94 L (0.25 gal)

 

 

 

 

 

 

 

FLUID FILTRATION

 

 

 

 

 

 

Main supply

 

10 µm

25 µm

25 µm

25 µm

25 µm

Pilot pressure supply

 

3 µm

3 µm

3 µm

3 µm

3 µm

 

 

 

 

 

 

 

FLUID HOSE CONNECTIONS

 

 

 

 

 

Pressure

 

-16

1-1/2 Code 61 or -20 JIC

1-1/2 Code 62

-32 SAE Code 61

-32 SAE Code 62

Return

 

-16

1-1/2 Code 61 or -20JIC

1-1/2 Code 61

-32 SAE Code 61

-32 SAE Code 61

Pilot pressure

 

-6

-06/-08 JIC

-06/-08 JIC

-6

-6

Pilot return

 

-6

-06/-08 JIC

-06/-08 JIC

-6

-6

Drain

 

-6

-08/-12 JIC IN, -12 OUT

-08/-12 JIC IN, -12 OUT

-06 IN, -08 OUT

-06 IN, -08 OUT

Hydrostatic bearing

 

-6

-06 JIC

-06 JIC

-6

-6

Maximum number of

stations/channels

4

4

4

1

1

 

 

 

 

 

 

 

DIMENSIONS AND WEIGHTS

 

 

 

 

 

Weight

 

70 kg (155 lb)

159 kg (600 lb)1

182 kg (600 lb)1

181 kg (550 lb)2

227 kg (550 lb)

Height

 

806 mm (31.75 in)

1067 mm (43 in)3

1067 mm (43 in)3

1092 mm (43.5 in)3

1229 mm (43.5 in)3

Width (base)

 

363 mm (14.3 in)

362 mm (25.75 in)

362 mm (25.75 in)

403 mm (15.9 in) max

387 mm (15.9 in)

Depth (base)

 

359 mm (14.1 in)

394 mm (15.5 in)

400 mm (15.75 in)

394 mm (15.5 in) max

530 mm (15.5 in)

 

 

 

 

 

 

 

Footnotes:

 

 

 

 

 

 

* 378 lpm (100 gpm) total, 189 lpm (50 gpm) per station maximum for multi-station flow, 295.2X station is 100 gpm

 

 

 

 

 

 

 

 

 

1 Standard size for single-station configuration; 227 kg (600 lb)

 

 

 

2 Standard size; with optional accumulator capacity the weight is 454 kg (650 lb) maximum

 

 

3 Standard size; with optional accumulator capacity the height is 2134 mm (55.3 in) maximum

 

 

 

 

 

 

 

 

 

Specifications are subject to change without notice. Contact MTS for verification of any critical specifications.

 

 

Note: Accumulator may extend beyond HSM height.