The versatile Bionix EnviroBath facilitates accurate and efficient mechanical testing of medical device and biomaterial specimens in fluids heated to body temperatures. Engineered for biomedical and general material test applications, the Bionix EnviroBath is easy to set up, operate, and maintain.
Highly reliable fluid temperature control system maintains constant specimen temperatures throughout the test
Leak-proof front and back access panels enable the easy installation and change out of grips, fixtures and test specimens
Quick, controlled filling and draining minimizes time between tests
Universal adapter design ensures compatibility with MTS electromechanical, electrodynamic and servohydraulic load frames
The versatile Bionix EnviroBath facilitates accurate and efficient mechanical testing of medical device and biomaterial specimens in fluids heated to body temperatures. Engineered for biomedical and general material test applications, the Bionix EnviroBath is easy to set up, operate, and maintain and is available in a range of volume configurations to accommodate a broad variety of test specimens. A universal adapter design ensures full compatibility with all MTS electromechanical, electrodynamic and servohydraulic load frame systems, as well as other electromechanical test systems.
GENERAL SPECIFICATIONS |
|
|
|
| |
TEMPERATURE |
|
|
|
| |
Range: | 5˚C above ambient to 40˚C |
|
|
|
|
Stability: | ±2˚C at 37˚C |
|
|
|
|
|
|
|
|
|
|
POWER (V AC, Hz, A) |
|
|
|
| |
US: | 120 V AC, 50/60 Hz, 11 A |
|
|
|
|
Europe: | 240 V AC, 50 Hz, 10 A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
BIONIX EnviroBath |
|
|
|
| |
| VOLUME | AXIAL FORCE | TORSIONAL FORCE | INTERNAL DIMENSIONS WXHXD | EXTERNAL DIMENSIONS WXHXD |
1 | 1 liter | 2.4 kN | 28 N.m | 100 x 200 x 56 mm '4 x 8 x 2.2 in | 180 x 295 x 95 mm '7 x 11.5 x 3.65 in |
6 | 6 liter | 2.4 kN | 28 N.m | 130 x 480 x 100 mm 5 x 19 x 3.9 in | 205 x 575 x 140 mm 8 x 22.5 x 5.5 in |
10 | 10 liter | 10 kN | 100 N.m | 215 x 305 x 150 mm '8.5 x 12 x 5.8 in | 295 x 395 x 190 mm '11.5 x 15.5 x 7.4 in |
OPTIONS |
|
|
|
|
| 1 LITER | 6 LITER | 10 LITER |
|
Sprayer Option |
| √ | √ |
|
Protein Based Fluid | √ | √ | √ |
|
Horizontal | √ | √ |
|
|
Digital Temperature Monitor | √ | √ | √ |
|
Upper Pull Rod (SST) | √ | √ | √ |
|
|
|
|
|
|
COMPATIBILITY MATRIX |
|
|
|
|
GRIPS AND FIXTURES | 1 LITER | 6 LITER | 10 LITER | PART NUMBER |
Bionix Vise Action Grips, 100 N | √ | √ | √ | 100-186-411 |
Model 642.001 Bend Fixture (SST) | √ | √ | √ | 100-201-456 (S/H & E/D) |
Bionix Manual Thumb Screw Grip, 100 N | √ | √ | √ | 100-167-987 |
Bionix Compression Platens, 40 mm | √ | √ | √ | 100-203-455 |
Bionix Spring Action Grips |
| √ | √ | 056-077-50x |
Bionix Compression Platens, 50 mm |
| √ | √ | 100-182-229 |
Bionix Vise Action Grips, 2 kN |
| √ | √ | 100-174-783 |
Bionix Roller Action Grips, 1 kN |
| √ | √ | 100-185-262 |
Model 642.01 Bend Fixture (SST) |
|
| √ | 100-203-453 (S/H & E/D) |
Bionix Compression Platens, 100 mm |
|
| √ | 100-182-227 |
Model 686.01A-31 Axial Torsional Grips (SST) |
|
| √ | 051-882-201 |
|
|
|
|
|
Note: EnviroBath 10 is compatible with customer-supplied spinal fixture per ASTM F1717-01. |
|
| ||
Some grips available in titanium. Contact MTS for additional information. |
|
|
|
|
* Vertical Orientation |
|
|
|
|
|
|
|
|
|
ELECTROMECANICAL LOAD FRAMES |
|
|
|
|
| 1 LITER | 6 LITER | 10 LITER |
|
MTS Single Column Standard Length | √ |
| √ |
|
MTS Single Column Extended Length | √ | √ | √ |
|
MTS Dual Column Standard and Extended Length | √ | √ | √ |
|
Legacy MTS load frames and Instron E/M load frames |
|
| Consult MTS |
|
|
|
|
|
|
ELECTRODYNAMIC LOAD FRAMES |
|
|
|
|
| 1 LITER | 6 LITER | 10 LITER |
|
MTS Acumen 1 | √ |
| √ |
|
MTS Acumen 3 | √ |
| √ |
|
MTS Acumen 3 A/T | √ |
| √ |
|
MTS Acumen 12 | √ | √ | √ |
|
MTS Acumen 12 A/T | √ |
| √ |
|
|
|
|
|
|
SERVOHYDRAULIC LOAD FRAMES |
|
|
|
|
| 1 liter | 6 liter | 10 liter |
|
Bionix Tabletop Axial or Axial/Torsional | √1 | √1, 2 | √ |
|
MTS Landmark3 | √ | √ | √ |
|
Legacy MTS load frames3 |
|
| Consult MTS |
|
|
|
|
|
|
1 Additional adapter required. |
|
|
|
|
2 Extended columns required. |
|
|
|
|
3 Cross-head mounted actuator. |