Conduct a broad range of single specimen damper testing, ranging from characterization and in-line production quality to custom applications such as NVH, high-velocity testing and road profile playback. The MTS damper testing portfolio features a selection of compact and portable electric and hydraulic solutions that are ideal for evaluating the vehicle dynamics of prototypes at the proving ground or tuning racecar dampers at the track.
MTS damper testing software is designed for ease-of-use, featuring wizard-based guides for test creation and execution and Excel-based macros for easy analysis and reporting.
MTS damper performance solutions employ high precision encoders (electric systems) or velocity preservation compensators (servohydraulic systems) to track command signals with very low distortion.
The EMA product line combines the latest linear electric actuator technology and high-performance FlexTest controls to deliver superior performance and highly precise results.
The Model 320 product line can test all types of ground vehicles, including motorcycles, scooters and ATVs; passenger cars, light and heavy trucks; as well as train cars and off highway vehicles.
|
Units |
10VS |
10VS HV |
20VS |
20VS HV |
Peak Force |
kN |
15.5 |
15.5 |
20 |
20 |
lbf |
3500 |
3500 |
4500 |
4500 |
|
Maximum Displacement |
mm |
150 |
150 |
150 |
150 |
in |
6 |
6 |
6 |
6 |
|
Maximum Velocity |
m/sec |
2 |
2.5 |
2 |
2.5 |
in/sec |
78 |
98 |
78 |
98 |
|
Stated Performance |
m/sec @ kN force |
2.0 @ 3.8 |
2.5 @ 6.0 |
2.0 @ 7.5 |
2.5 @ 6.0 |
|
|
|
|
|
|
Note: Specifications subject to change |
|||||
|
|||||
|
|||||
Power Supplies |
Voltage |
Phase |
A in |
A out |
|
SYD-10VS |
200-240 |
3 |
46.1 |
33 |
|
380-500 |
3 |
26.6 |
17 |
||
SYD-20VS |
380-500 |
3 |
41 |
28 |
|
|
|||||
Note:Assumes 90° C insulation on all cables |
|
Units |
EMA-2K |
EMA-4K |
EMA-6K |
Dynamic Force |
kN |
8.9 |
17.8 |
26.7 |
lbf |
2000 |
4000 |
6000 |
|
Static Force |
kN |
2.1 |
4.2 |
6.2 |
lbf |
475 |
950 |
1400 |
|
Static Force with Static Load Compensation |
>kN |
7 |
13 |
20 |
lbf |
1475 |
2950 |
4400 |
|
Peak Velocity |
m/sec |
4 |
4 |
4 |
in/sec |
157 |
157 |
157 |
|
Velocity at Peak Force |
m/sec |
2.5 |
2.5 |
2.5 |
in/sec |
98 |
98 |
98 |
|
Stroke |
mm |
203 |
203 |
203 |
in |
8 |
8 |
8 |
|
Frequency Response |
Hz |
100 |
100 |
100 |
Temperature Monitoring |
Specimen |
Non-contacting IR with software monitoring |
||
Motor |
Non-contacting IR with process meter monitoring |
|||
Digital Encoder Accuracy |
μ |
1 |
1 |
1 |
Noise Level – Typical |
dbA |
<60 |
<60 |
<60 |
Load Cell |
lbf |
2000 |
5000 |
10000 |
Type |
Interface |
|||
Waveforms Supported |
Type |
Sine, Triangle, Square, Frequency Sweep, Custom Profile |
||
Software |
SHOCK™ Test Control and Damper Analysis Software |
|||
Bearing Material |
Type |
Dry Linear Bearing – Maintenance Free Replacement Interval: 2-5 yrs |
||
Facility Requirements1 |
V |
220 |
220 |
220 |
A |
30 |
60 |
100 |
|
Air Supply |
PSI |
100 |
100 |
100 |
BAR |
7 |
7 |
7 |
|
CFM |
35 |
35 |
35 |
|
|
|
|
|
|
Specifications subject to change |
||||
1. MTS can supply transformers for voltages other than 220V III-Phase |
|
Units |
Model 849.15 |
Model 849.25 |
Actuator Maximum Dynamic Force |
kN |
15 |
25 |
>kip |
3.3 |
5.5 |
|
Actuator Rod Diameter |
mm |
70 |
|
Actuator Stroke |
kN |
250 |
|
Actuator Hydrostatic Bearing |
|
Standard |
|
Actuator Anti-Rotate |
|
Standard |
|
Servovalve |
lpm |
126 |
188 |
gpm |
33 |
50 |
|
Friction Force Servovalve |
lpm |
3.8 |
3.8 |
gpm |
1 |
1 | |
Servovalve Shutoff |
|
Manual |
|
Hydraulic Low Flow |
|
Standard, limits actuator to 10 mm/s |
|
Friction Force Load Cell |
kN |
7 |
|
lbs |
1500 |
||
Sideload |
|
Hydraulic, dynamic (optional) |
|
Pneumatic, static (optional) |
|||
Accumulators |
liters |
8 |
15 |
Test Space |
mm |
1200 |
|
HSM |
|
Integral to accumulator manifold |
|
Performance:
|
m/s @ kN |
3.2 @ 0 |
2.9 @ 0 |
2.3 @ 5 |
2.5 @ 5 |
||
0.7 @ 10 |
2.0 @ 10 |
||
|
1.4 @ 15 |
||
|
0.6 @ 18 |
|
Units |
LEMA-2K |
Dynamic Force |
kN |
8.9 |
lbf |
2000 |
|
Static Force |
kN |
2.1 |
lbf |
475 |
|
Static Force with Static Load Compensation |
kN |
7 |
lbf |
1475 |
|
Peak Velocity |
m/sec |
4 |
in/sec |
157 |
|
Velocity at Peak Force |
m/sec |
2.5 |
in/sec |
98 |
|
Stroke |
mm |
203 |
in |
8 |
|
Frequency Response |
Hz |
100 |
Temperature Monitoring |
Specimen |
Non-contacting IR with software monitoring |
Motor |
Non-contacting IR with process meter monitoring |
|
Digital Encoder Accuracy |
μ |
1 |
Noise Level – Typical |
dbA |
<60 |
Load Cell |
lbf |
2000 |
Type |
Interface |
|
Waveforms Supported |
Type |
Sine, Triangle, Square, Frequency Sweep, Custom Profile |
Software |
SHOCK™ Test Control and Damper Analysis Software |
|
Bearing Material |
Type |
Dry Linear Bearing – Maintenance Free Replacement Interval: 2-5 yrs |
Facility Requirements1 |
V |
220 |
A |
30 |
|
Air Supply |
PSI |
100 |
BAR |
7 |
|
CFM |
35 |
|
|
|
|
Specifications subject to change |
||
1. MTS can supply transformers for voltages other than 220V III-Phase |