Open Monday - Friday 08.30 – 17.30 | Call Center 02 101 4427

Damper Durability Test Systems

Subject single or multiple damper specimens to millions of durability cycles, or run short bursts of high-performing cycles to measure damping characteristics. MTS damper durability systems combine highly stiff, self-supporting bases to withstand high inertial loading and selectable three-stage servovalves to perform high velocity durability testing on even the largest dampers and struts.

  • Durability
  • Characterization
  • Dampers
  • Struts
true
true

Video Product

KEY PRODUCT FEATURES

Versatile

Models 850 & 852 deliver the force required for multi-specimen durability testing while supporting an array of optional hardware for a wide variety of performance testing

Accurate / Repeatable

Capable of generating a full spectrum of control waveforms, including sine, ramp, square, sine-on-sine, sine sweep, dual rate sine, dual rate ramp and user defined block cyclic.

Advanced Safety Features

A certified, safety-rated Programmable Logic Controller (PLC) ensures the safety of human operators and ISO 13849 compliance

Efficient Operation

MTS Damper Testing Software enables easy test setup, flexible yet comprehensive data acquisition, automated test data reports and numerous methods of presentation and analysis

MODEL COMPARISON

TECHNICAL OVERVIEW

 

Units

Model 849.15

Model 849.25

Actuator Maximum Dynamic Force

kN

15

25

kip

3.3

5.5

Actuator Rod Diameter

mm

70

Actuator Stroke

kN

250

Actuator Hydrostatic Bearing

 

Standard

Actuator Anti-Rotate

 

Standard

Servovalve

lpm

126

188

gpm

33

50

Friction Force Servovalve

lpm

3.8

3.8

gpm

1

1

Servovalve Shutoff

 

Manual

Hydraulic Low Flow

 

Standard, limits actuator to 10 mm/s

Friction Force Load Cell

kN

7

lbs

1500

Sideload

 

Hydraulic, dynamic (optional)

Pneumatic, static (optional)

Accumulators

liters

8

15

Test Space

mm

1200

HSM

 

Integral to accumulator manifold

Performance:


For 3 cycles at 100 mm stroke sine wave command

m/s @ kN

3.2 @ 0

2.9 @ 0

2.3 @ 5

2.5 @ 5

0.7 @ 10

2.0 @ 10

 

1.4 @ 15

 

0.6 @ 18

Machine Specifications

Units

Model 850.25

Model 850.50

Actuator Rod Diameter

mm

80

80

in

3.15

3.15

Test Space (Actuator Face to Load Cell)

maximum

mm

1560

1540

minimum

mm

160

132

Frame Dynamic Load Rating

kN

50

50

kip

11

11

Floor Mount

 

Frame Bolted to Concrete (optional vibration isolation system available)

HSM

lpm

Integral to Accumulator manifold, 300 lpm max

Actuator Hydrostatic Bearing

Yes

Actuator Stroke

mm

250

250

in

10

10

Heavy Duty Anti-Rotate

 

Yes

Safety Low Flow

 

Yes

Accumulator

l

19 Liter Pressure and Return

Machine Specifications

Units

Model 852.25

Model 852.50

Model 852.67

Actuator Rod Diameter

mm

80

80

80

in

3.15

3.15

3.15

Test Space (Actuator Face to Load Cell)

 

maximum

mm

1575

1575

1575

minimum

mm

180

180

180

Frame Dynamic Load Rating

kN

67

67

67

kip

15

15

15

Floor Mount

 

Frame Bolted to Concrete (optional vibration isolation system available)

HSM

lpm

Integral to Accumulator manifold, 284 lpm max

Actuator Hydrostatic Bearing

Yes

Actuator Stroke

mm

250

250

250

in

10

10

10

Heavy Duty Anti-Rotate

 

Yes

Safety Low Flow

 

Yes

Accumulator (pressure and return)

l

19

19

38

      

  1. Servovalves (high and low flow modes): Achieve higher-precision in low-velocity tests while in low-flow mode with the addition of secondary servo valves.

  2. Custom Accumulation: Increase system performance with additional accumulators. System can be customizable to meet unique testing needs.

  3. Multi-specimen Fixtures: Enable testing of up to 8 specimens simultaneously. Individual force transducers for each specimen are used to provide accurate data acquisition

  4. Side-load Actuators: Simulate real-world loading conditions by providing an adjustable lateral force on damper test specimens.

  5. Environmental Chamber: Test dampers in real-world hot and cold conditions with an environmental chamber mounted in the test frame.

  6. Water-jacket Cooling: Reduce testing downtime by keeping dampers within a test specification’s required temperatures ranges.

  7. Vibration Isolation: Reduce force transmission into the floor and allow test systems to be installed into facilities sensitive to vibration.

  8. Mud & Slurry Simulation: Simulate testing dampers in real-world muddy conditions. Regulate the amount and consistency of mud slurry with this self-contained mud-slurry option.

ISO 13849-compliant MTS damper test systems employ a certified, safety-rated Programmable Logic Controller (PLC) to manage all safety functions and subsystems, including:

  • Safe Speed
  • Safe Isolation / Safe Power Off
  • Three-position mode switch (Off / Low / High)
  • Safety-rated valves
  • Test Area Enclosures
  • E-stops & Station stops